DESCRIPTION
Medium strength monolithic floor flush with the underlying plate. Thickness of approx. 1.5-3.0mm of self-levelling, anti-static resin applied to the concrete plate which is dry and has been roughened mechanically.
WHERE IT IS APPLIED
Suitable for loads (l) and operations (L) (See DIN Standard 1100) Electronic industries, laboratories, operating theatres, clean rooms, explosive environments, areas with magnetic guides etc..
SPECIFICATION FOR THE DESIGN
CHEMIDUR CE monolithic industrial flooring comprising:
- PREPARATION
Prepare the application surface by using mechanical equipment and dust extraction
- SURFACE LAYER
Application of epoxy and quartz primer. Provision of copper strips connected to the earth. A mix of special conductive aggregates on a homogeneous granulometric curve and synthetic resins, applied with a notched trowel and finished with a spiked roller to remove surface bubbles
- LOAD BEARING CONCRETE PLATE
Cured concrete plate (Formulated and reinforced concrete to achieve the performance required by the design of the project. Resistance, durability and controlled shrinkage are basic elements of DURSICAL). Thickness and reinforcement requires a design project
- SEPARATION BARRIER
PVC isolation layer between the base and the flooring Separation from the elevated structures
- SUPPORTING BASE
Soil stabilised using the Westergaard method
|
|